GLFC 0604-1204 BD2 (153 – 326 kW)
The GLFC 0604-1204 BD2 air-cooled free-cooling chillers are designed to provide chilled water for process applications
- Version with 4 scroll compressors
- SEPR-HT values up to 6.1
- 13 models in ErP 2021 compliant design to EU 2016/2281
- Versions available as Standard or Super Silent execution (SL)
Datos importantes
- 4 scroll impressors
- 2 refrigeration circuits
- Refrigerant R-410A (GWP 2088)
- Suitable for outdoor installation
- Air side Cu/Al heat exchanger
- Optional protective coating
- Water side plate heat exchanger
- Variable speed fans optional
- Modulating valves optional
- Auto-adaptive microprocessor control
- Connection to a BMS via Modbus, LonWorks and BACnet optional
- Free-cooling operation down to -30 ° C outdoor temperature optionally possible
- Chilled water operation possible at outdoor temperatures of -10 °C to +46 °C
- Chilled water temperature -8 °C to +15 °C depending on the outside temperature
Product information
Product description
GLFC chillers are suitable for process applications, such as data center cooling or machine cooling. Compared to standard chillers, free-cooling units are equipped with an additional air-cooled heat exchanger. The additional heat exchanger is flown through by water-glycol mixture from the system when the internal waterways are switched. The water-glycol mixture is cooled or pre-cooled by the outside air. If the outside air temperature drops about 1 K below the return water temperature of the chilled water system, the free cooling function is activated. Free cooling and mechanical refrigeration take place simultaneously during the transitional period to achieve maximum efficiency. If the outside temperatures are sufficiently cold, the complete cooling capacity can be achieved by free cooling. The compressors remain switched off. Only the fans remain in operation. With the free-cooling function, it is possible to ensure excellent energy efficiency over the course of the year.
Características del producto
BMS connection possible
For these devices, serial interface cards with different protocols are available for connection to a higher-level building management system.Cooling
The unit is suitable for cooling.Free cooling
Device with the additional function "free cooling". By using an additional heat exchanger, it is possible to cool the cooling medium directly through the outside air without activating the compressor.Outdoor installation
The device has been designed for outdoor installation on or near the building to be climatized. The outside air is required to ensure the function of the unit.
productos relacionados
Hydro-DENCO® High Capacity CRAH
Go to product- 8-unit sizes with cooling capacity from 42 to 260 kW
- Chilled water system
- Designed for dry cooling, optimized for high water medium temperatures
- Integrated electronic pressure independent control valve (Energy valve)
- 1-4 Quality brand EC fans - versions with Active Power Factor Correction (APFC) available
Configurar el producto
Para calcular el producto y obtener los datos técnicos, utilice nuestra herramienta de selección.
Loading translations
Loading translations
Documentos
Choose language
Filtrar por tipo de documento
- Postventa
Document title and no. | Type | Idioma | Format | Descargar | Compartir enlace | |||
---|---|---|---|---|---|---|---|---|
Technical Data GLFC 0152-1204 BD2 (R2)2009-0007 | Data sheet | English | Activo | 22/07/2019 |