Ultra-DENCO® (CRAH)

Fast facts

  • Execution in 2 delivery units: fan and heat exchanger chamber
  • Easy installation in buildings with standard door heights due to delivery in 2 parts (height 1960 mm + 600 mm)
  • Footprints (L x D) from 900 x 1335 mm to 980 x 3307 mm
  • Air flow from top to bottom (downflow)
  • Can be set up in rooms with or without a floor void
  • Energy-efficient, free discharge from the radial fans without unnecessary diversions
  • Large heat exchanger, version for low or high temperature differences
  • Wide operating limits (e.g. 10-40 °C air intake temperature)
  • Optional electric heater and steam humidifier
  • Operation with ISO Coarse 65% (G4) or ISO ePM2.5 65% (F7) filters or without filter
  • Free air intake, with protection grille, with duct connection flange or with air intake damper
  • Electrical and hydronic energy monitoring, automatic transfer switches and many other electrical functions
  • Modern control package with 4.3-inch touch screen, interface to building management systems (BMS)
  • Internal network solution (DENCONet) for controlling several devices in a group
  • Ideal for connection to a FläktGroup chiller with free cooling (FGFC/ GLFC series)

Product information

Product description

Ultra-DENCO® was specially designed for the performance and efficiency requirements of data centres, as well as server rooms, UPS and technical rooms. Due to the structure in 2 separate delivery units (heat exchanger and fan chamber), which can be stacked on top of each other on the construction site, a total height of almost 2.6 m can be achieved while at the same time being easy to bring into buildings with standard door heights. The enormous space available in the 1960 mm high upper delivery unit is used to the maximum by the diagonally arranged hydrophilically coated heat exchanger. This maximises performance per footprint (kW/m²) and minimises energy consumption for airflow caused by pressure losses. Heat exchanger variants are available for small temperature differences (e.g. 7/12 °C or 10/16°C) or large temperature differences (e.g. 20/30 °C). Even at higher system temperatures high cooling capacities are achieved.

1 to 4 EC fans with or without APFC (electronic harmonic filter) of the latest generation from are recognised quality supplier are used. The arrangement directly behind the discharge grille results in particularly energy-efficient operation since pressure losses on the discharge side are reduced by eliminating additional diversions.

The device is particularly suitable for rooms with floors voids. In this application, the fan section remains below the false floor and serves as a base stand for the heat exchanger section. Various raised floor heights can be implemented. An application without a floor void is also possible without any problems, as the fan section is equipped with an all-round protection against intrusion. Alternatively, the air can be blown out only to the front or only to the rear. The water connections can be made from below, from the front or from the side.

Ultra-DENCO® represents a particularly flexible and future-proof system, since a connection to a wide variety of cooling systems is possible via the chilled water circuit. As a system solution, FläktGroup offers suitable chillers for indoor (FGWC/GLWC) or outdoor installation (FGAC), as well as chillers with an integrated free cooling function (FGFC/GLFC). Furthermore, heat recovery can be realised with the help of 4-pipe heat pumps HeaMo (FGAS), so that the waste heat from the cooling process can be used as heating energy for heating the building free of charge.

A major advantage is that no refrigerant is used in the installation room since the energy is transported solely via the chilled water circuit. Thus, the choice of refrigerant and the refrigerant charge depends solely on the independent refrigeration system, which is usually installed outside. In addition, chillers and Ultra-DENCO® precision air conditioning cabinets can be replaced independently of one another as part of retrofit measures.

Product features

Related products

Configure product

For product calculation and performance data of this product, please use our product configuration tool.

Spare Parts Enquiry (CARE by FläktGroup)

Loading translations

Loading translations

Loading translations

Loading translations

Loading translations
Loading translations

Documents

Choose language

Filter by document type

    • After-sales
    • Pre-sales
    Document title and no.TypeLanguageFormatDownloadShare link
    Ultra-DENCO operation manual2011-0100
    Maintenance
    Installation
    Commissioning
    English
    12/1/2022
    Ultra-DENCO® INSTALLATION10883
    Installation
    Multi
    English, Français, Deutsch, Italiano, Polski, Español, Türkçe, Čeština (Česko), Français (Belgique), Deutsch (Österreich)
    Active4/23/2025
    Data Centre Cooling - DENCO Leaflet10322
    Marketing
    English
    Active4/30/2025
    Viewing 3 of 3 documents